Infant Radiant Warmer (Am-93 Series)

Model NO.: AM-93 series
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: Gxzz1234567890
Incubator: Baby
Trademark: AMISMED
Origin: China
Model NO.: AM-93 series
Medical Device Regulatory Type: Type 2
Medical Devices Reg./Record No.: Gxzz1234567890
Incubator: Baby
Trademark: AMISMED
Origin: China
Infant Radiant Warmer (Am-93 Series)
Infant Radiant Warmer (Am-93 Series)

Brief introduction:
- Three control modes: Pre-warm mode, manual mode and baby mode controlled by micro-computer;
- Set temperature and baby temperature can be displayed separately;
- Horizon angle of heater head and inclination of the bassinet can be adjusted;
- The panels around bassinet can be turned outward;
- X-ray cassette under the bassinet;
- APGAR timer;
- Timer to count phototherapy time,
- Failure alarm indication;
- RS-232 connector;

Standard configuration:
- AM-93: The warmer module, bassinet, main column, stand, controller, I. V. Pole and tray.
- AM-93B: Based on AM-93, added with the phototherapy unit (with LED bulbs)
- AM-93A: Based on AM-93B, added with the Breath resuscitation bag, Infant head fixing unit.
- All of above thress models cna be configured with vertical height adjustment stand.

Specification:
- Power supply: AC220V~230V/50Hz
- Maximum power Output:
700W (AM-93 for fixed stand)
750W (AM-93 for VHA stand)
750W (AM-93A/AM-93B for fexed stand)
800W (AM-93A/AM-93B for VHA stand)
- Mode of control: Pre-warm mode control, manual mode control and baby mode controlled by micro-computer.
- Baby mode temperature control range: 34.5~37.5º C
- Temperature sensor display range: 5~65º C
- Accuracy of skin temperature sensor: ≤ 0.3º C
- Deviation between the measure by the skin temperature sensor and control temperature: ≤ 0.5º C
- Temperature uniformity of mattress: ≤ 2º C
- Angle of warmer module: 0° , 30° , 60° For two ways
- Inclination of the bassinet: ± 10°
- APGAR timer: It will give sound when the unit tones at 1', 5', 10'
- Failure alarm: Over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
- Max. Billirubin radiation on the mattress effective range: ≥ 1000uW/cm2 (AM-93B, AM-93A)
- Bilirubin uniformity of radiating on the mattress effective range: >0.4 (AM-93A/AM-93B)
- Wave length of blue light: 420~470nm

Environmental temperature
Operating range: 18~30º C
Ambient air movement rate: ≤ 0.3m/s

For more information, please visit our website or contact us directly with your questions or inquiries. We are looking forward to receiving your correspondences in the near future. Infant Radiant Warmer (Am-93 Series)
Infant Radiant Warmer (Am-93 Series)

Brief introduction:
- Three control modes: Pre-warm mode, manual mode and baby mode controlled by micro-computer;
- Set temperature and baby temperature can be displayed separately;
- Horizon angle of heater head and inclination of the bassinet can be adjusted;
- The panels around bassinet can be turned outward;
- X-ray cassette under the bassinet;
- APGAR timer;
- Timer to count phototherapy time,
- Failure alarm indication;
- RS-232 connector;

Standard configuration:
- AM-93: The warmer module, bassinet, main column, stand, controller, I. V. Pole and tray.
- AM-93B: Based on AM-93, added with the phototherapy unit (with LED bulbs)
- AM-93A: Based on AM-93B, added with the Breath resuscitation bag, Infant head fixing unit.
- All of above thress models cna be configured with vertical height adjustment stand.

Specification:
- Power supply: AC220V~230V/50Hz
- Maximum power Output:
700W (AM-93 for fixed stand)
750W (AM-93 for VHA stand)
750W (AM-93A/AM-93B for fexed stand)
800W (AM-93A/AM-93B for VHA stand)
- Mode of control: Pre-warm mode control, manual mode control and baby mode controlled by micro-computer.
- Baby mode temperature control range: 34.5~37.5º C
- Temperature sensor display range: 5~65º C
- Accuracy of skin temperature sensor: ≤ 0.3º C
- Deviation between the measure by the skin temperature sensor and control temperature: ≤ 0.5º C
- Temperature uniformity of mattress: ≤ 2º C
- Angle of warmer module: 0° , 30° , 60° For two ways
- Inclination of the bassinet: ± 10°
- APGAR timer: It will give sound when the unit tones at 1', 5', 10'
- Failure alarm: Over temperature alarm, deviation alarm, sensor failure alarm, power failure alarm, setting alarm, checking alarm and so on.
- Max. Billirubin radiation on the mattress effective range: ≥ 1000uW/cm2 (AM-93B, AM-93A)
- Bilirubin uniformity of radiating on the mattress effective range: >0.4 (AM-93A/AM-93B)
- Wave length of blue light: 420~470nm

Environmental temperature
Operating range: 18~30º C
Ambient air movement rate: ≤ 0.3m/s

For more information, please visit our website or contact us directly with your questions or inquiries. We are looking forward to receiving your correspondences in the near future.

Goji Berry ( [Goji" means [happy") , also called wolfberry, has been used for thousands of years by herbalists in China to protect the liver, help eyesight, boost immune function, improve circulation, and promote longevity and overall well being. It has only recently gained popularity in the west, it has become so polar, in fact, the Time Magazine recently named the Goji berry as [super-fruit" of the year. A big reason why Goji berries have quickly become a favorite nutritional supplement is that its impressive list of ingredients. The Goji berry, also called the wolfberry, is a bright purplish red or purple red berry that comes from a shrub that is native to China. In Asia, goji berries have been eaten for generation in the hope of living longer.    

 

Grade C Goji Berry

Grade C Goji Berry,Grade C Dried Goji Berry,Grade C Wolfberry,C Grade Dried Goji Berries

ZHONGNING JIDING BIO SCIENCE DEVELOPMRNT CO., LTD. , http://www.jidinggouqi.com

Posted on